FAN & FILTER
Exhausted air Inhalation Type / Side attachment Type
Type
AFS-N30 / FHG-150
AFS-N60 / FHG-200
AFS-N70 / FHG-250
AFS-N90 / FHG-300
Rated power consumption
19W / 17W
39.5W / 34W
38W / 35W
53W / 40W
Dimension (WxHxD)(mm)
148 x 148 x 70(13)
205 x 205 x 70(13)
255 x 255 x 85(13)
320 x 320 x 98(13)
Weight
1.1kg
1.2kg
1.5kg
1.8kg
FAN SPEED(rpm)
2,650 / 3,100
2,900 / 3,300
2,900 / 3,400
2,800 / 3,300
AIR VOLUME(m2/h)
139 / 190
330 / 390
410 / 500
725 / 830
Input power
1Ph 220V, 50/60Hz
Temp. range / Motor service life
10 ~ 70℃, Average 50,000hr (ambient temp. 20℃ / humidity 60% )
Attachment b
Exhausted air Inhalation type / Side attachment type
Other
When FHG model selects only the cover except motor (including filter)
Exhausted air Inhalation Type / Ceiling attachment Type
Type
AFT-130
Rated power consumption
200W
Dimension (WxHxD)(mm)
440 x 145 x 440
Weight
6kg
FAN SPEED(rpm)
2,950
AIR VOLUME(m2/h)
945
Input Power
1Ph 220V, 50/60Hz
Temp. range / Motor service life
10 ~ 70℃, Average 50,000hr (ambient temp. 20℃ / humidity 60%)
Attachment b
Exhausted air Inhalation type / Ceiling attachment type
Features
What is AIRMAJOR Fan & Filter?
This is used when internal temperature of panel is higher than external temperature. This is to block the external dust or pollutants through filter, which are accompanied when external air flows into come into by absorption fan. This is a system that maintains the internal temperature of control panel through this process and discharge the heated heat outside through discharge fan. (But, not available to block the inflow of fine dust or humidity)
Features of AIRMAJOR Fan & Filter
-
Filter can be used again by cleaning with neutral agent or removing dusts with compressed air. .
-
Using a ball bearing fan motor, the average life of Fan Cooler is 50,000hr. (ambient temp. 20℃, humidity 60%).
-
Available to use in high temperature range 10~70℃.
-
Filter uses non-flammable materials which inhibits ignition by external flame or short circuit.
FAN & FILTER
Type | AFS-N30 / FHG-150 | AFS-N60 / FHG-200 | AFS-N70 / FHG-250 | AFS-N90 / FHG-300 |
---|---|---|---|---|
Rated power consumption | 19W / 17W | 39.5W / 34W | 38W / 35W | 53W / 40W |
Dimension (WxHxD)(mm) | 148 x 148 x 70(13) | 205 x 205 x 70(13) | 255 x 255 x 85(13) | 320 x 320 x 98(13) |
Weight | 1.1kg | 1.2kg | 1.5kg | 1.8kg |
FAN SPEED(rpm) | 2,650 / 3,100 | 2,900 / 3,300 | 2,900 / 3,400 | 2,800 / 3,300 |
AIR VOLUME(m2/h) | 139 / 190 | 330 / 390 | 410 / 500 | 725 / 830 |
Input power | 1Ph 220V, 50/60Hz | |||
Temp. range / Motor service life | 10 ~ 70℃, Average 50,000hr (ambient temp. 20℃ / humidity 60% ) | |||
Attachment b | Exhausted air Inhalation type / Side attachment type | |||
Other | When FHG model selects only the cover except motor (including filter) |
Exhausted air Inhalation Type / Ceiling attachment Type | ||||
---|---|---|---|---|
Type | AFT-130 | |||
Rated power consumption | 200W | |||
Dimension (WxHxD)(mm) | 440 x 145 x 440 | |||
Weight | 6kg | |||
FAN SPEED(rpm) | 2,950 | |||
AIR VOLUME(m2/h) | 945 | |||
Input Power | 1Ph 220V, 50/60Hz | |||
Temp. range / Motor service life | 10 ~ 70℃, Average 50,000hr (ambient temp. 20℃ / humidity 60%) | |||
Attachment b | Exhausted air Inhalation type / Ceiling attachment type |
Features
What is AIRMAJOR Fan & Filter?
This is used when internal temperature of panel is higher than external temperature. This is to block the external dust or pollutants through filter, which are accompanied when external air flows into come into by absorption fan. This is a system that maintains the internal temperature of control panel through this process and discharge the heated heat outside through discharge fan. (But, not available to block the inflow of fine dust or humidity)
Features of AIRMAJOR Fan & Filter
- Filter can be used again by cleaning with neutral agent or removing dusts with compressed air. .
- Using a ball bearing fan motor, the average life of Fan Cooler is 50,000hr. (ambient temp. 20℃, humidity 60%).
- Available to use in high temperature range 10~70℃.
- Filter uses non-flammable materials which inhibits ignition by external flame or short circuit.
|
|
||
|
|
|
|
|