產(chǎn)品詳情
Hawke帶膠泥鎧裝防爆格蘭(ICG653/UNIV)
Hawke帶膠泥鎧裝防爆格蘭(ICG653/UNIV)
Hawke帶膠泥鎧裝防爆格蘭(ICG653/UNIV)
Hawke代理商:上海頤品自動化科技有限公司(Hawke cable gland)
Hawke防爆格蘭,Hawke防爆密封接頭,Hawke防爆堵頭,Hawke防爆變徑,Hawke防爆呼吸閥,Hawke防爆接線箱
Hawke防爆格蘭,Hawke防爆密封接頭,Hawke防爆堵頭,Hawke防爆變徑,Hawke防爆呼吸閥,Hawke防爆接線箱
HAWKE ICG 653/UNIVERSAL CABLE GLANDS
Hawke ICG 653/Universal cable glands are suitable for use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.
For particular use with:-
a) Cable inner sheaths that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers.
b) Cables that exhibit ‘cold flow’ characteristics.
c) Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area.
Hawke ICG 653/Universal cable glands are dual certified Exd and Exe and suitable for installation in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC, 5.5-78.0mm outside cable diameters.
When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.
? Exdb IIC Gb, Exe IIC Gb, Extb IIIC, Db Aromoured Cables ATEX & IECEx Cable Gland.
Hawke ICG 653/Universal cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.
- Flameproof Exdb
- Increased Safety Exeb
- Dust Extb
- Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx
HAWKE ICG 653/UNIVERSAL CABLE GLAND TECHNICAL SPECIFICATION
- Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exeb IIC Gb, Extb IIIC Db
- Certificate No’s – baseefa06ATEX0058X and IECEx BAS 06.0015X
- Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC
- Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31
- Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X
- Deluge Protection – DTS01
- Operating Temperature Range -60°C to +80°C
CABLE GLAND SELECTION TABLE FOR HAWKE ICG 653/UNIVERSAL
Hawke Size Ref. |
Entry Thread Size | Cable Acceptance Details |
‘G’ Compressed Length |
Hexagon Dimensions | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inner Sheath/ Cores | ‘B’ Outer Sheath | ‘C’ Armour/Braid | ||||||||||||
Metric | NPT * |
‘D’ Max. Over Cores |
‘E’ Max . Inner Sheath |
NOTE 1 Max. No. Of Cores |
NOTE 2 Max. No. Of Cores |
Across Flats |
Across Corners |
|||||||
Standard | Option | Min. | Max. | Orientation 1 | Orientation 2 | |||||||||
Os | M20 | ?” | – | 8.9 | 10.0 | 12 | 6 | 5.5 | 12.0 | 0.8 / 1.25 | 0 / 0.8 | 67.0 | 24.0 | 26.5 |
O | M20 | ?” | – | 8.9 | 10.0 | 12 | 6 | 9.5 | 16.0 | 0.8 / 1.25 | 0 / 0.8 | 67.0 | 24.0 | 26.5 |
A | M20 | ?” | ?” | 11.0 | 12.5 | 15 | 10 | 12.5 | 20.5 | 0.8 / 1.25 | 0 / 0.8 | 67.0 | 30.0 | 32.5 |
B | M25 | 1″ | ?” | 16.2 | 18.4 | 30 | 21 | 16.9 | 26.0 | 1.25 / 1.6 | 0 / 0.7 | 73.6 | 36.0 | 39.5 |
C | M32 | 1?” | 1″ | 21.9 | 24.7 | 42 | 42 | 22.0 | 33.0 | 1.6 / 2.0 | 0 / 0.7 | 78.0 | 46.0 | 50.5 |
C2 | M40 | 1?” | 1?” | 26.3 | 29.7 | 60 | 60 | 28.0 | 41.0 | 1.6 / 2.0 | 0 / 0.7 | 82.4 | 55.0 | 60.6 |
D | M50 | 2″ | 1?” | 37.1 | 41.7 | 80 | 80 | 36.0 | 52.6 | 1.8 / 2.5 | 0 / 1.0 | 88.7 | 65.0 | 70.8 |
E | M63 | 2?” | 2″ | 47.8 | 53.3 | 100 | 100 | 46.0 | 65.3 | 1.8 / 2.5 | 0 / 1.0 | 92.7 | 80.0 | 88.0 |
F | M75 | 3″ | 2?” | 59.0 | 66.2/65.3 ? | 120 | 120 | 57.0 | 78.0 | 1.8 / 2.5 | 0 / 1.0 | 99.4 | 95.0 | 104.0 |
CABLE GLAND MATERIAL & FINISH
Hawke ICG 653/Universal cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.
PREPARING CABLE & GLAND FOR INSTALLING HAWKE ICG 653/UNIVERSAL
CABLE PREPARATION
Strip Cable to suit equipment as shown above and expose the armour/braid ‘I’ removing all cable fillers.
‘I’ = 20mm for cable gland sizes Os to A ‘I’ = 25mm for cable gland sizes B to C2 ‘I’ = 32mm for cable gland sizes D to F ‘II’ to suit equipment. If required, fit shroud.
CABLE GLAND PREPARATION
Push the cable through the armour spigot (4). Spread armour/braid over the armour spigot (4) until the end of the armour/braid is up against the shoulder of the armour cone. Position the armour clamping ring (3).
Remove the inner seal (5) from the entry (6). Place the entry (6) over the armour spigot (4). Move the sub-assembly (1) and (2) up to meet the entry (6).
Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.
Hawke帶膠泥鎧裝防爆格蘭(ICG653/UNIV)Hawke代理商:上海頤品自動化科技有限公司(Hawke cable gland)
Hawke防爆格蘭,Hawke防爆密封接頭,Hawke防爆堵頭,Hawke防爆變徑,Hawke防爆呼吸閥,Hawke防爆接線箱 Hawke防爆格蘭,Hawke防爆密封接頭,Hawke防爆堵頭,Hawke防爆變徑,Hawke防爆呼吸閥,Hawke防爆接線箱